<?xml version="1.0"?>
<!DOCTYPE article SYSTEM "journalpublishing.dtd">
<article article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="archive">gsminmag</journal-id>
<journal-title>Mineralogical Magazine</journal-title>
<abbrev-journal-title abbrev-type="full">Mineralogical Magazine</abbrev-journal-title>
<issn pub-type="ppub">0026-461X</issn>
<publisher>
<publisher-name>Mineralogical Society</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.1180/minmag.1975.040.309.13</article-id>
<title-group>
<article-title>A New Miniphotometer for Teaching and Routine Work in Ore Microscopy</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Tarkian</surname>
<given-names>M.</given-names>
</name></contrib>
<contrib contrib-type="author">
<name>
<surname>Stumpfl</surname>
<given-names>E. F.</given-names>
</name>
<xref ref-type="author-notes" rid="FN1">1</xref></contrib>
<contrib contrib-type="author">
<name>
<surname>Matthies</surname>
<given-names>H.</given-names>
</name></contrib>
<aff>Mineralogisch-Petrographisches Institut, Universit&#x00E4;t Hamburg</aff></contrib-group>
<author-notes>
<fn fn-type="present-address" id="FN1"><label>1</label><p>Present address: Montanistische Hochschule, Leoben, Austria</p></fn></author-notes>
<pub-date pub-type="ppub">
<month>3</month>
<year>1975</year>
</pub-date>
<volume>40</volume>
<issue>309</issue>
<fpage>97</fpage>
<lpage>103</lpage>
<history>
<date date-type="received">
<day>18</day>
<month>3</month>
<year>1974</year>
</date>
<date date-type="rev-recd">
<day>1</day>
<month>1</month>
<year>1975</year>
</date></history>
<copyright-statement>Copyright &#x00A9; 1975, The Mineralogical Society</copyright-statement>
<copyright-year>1975</copyright-year>
<abstract>
<title>Summary</title>
<p>A simple and easy-to-use miniphotometer has been designed; the expense involved amounts to only a fraction of that required for large commercially available microphotometers.</p>
<p>The instrument can be employed for routine investigations and for teaching reflected light microscopy in conjunction with standard reflected light microscopes.</p>
<p>The reflectance of grains down to 50 &#x00B5;m size can be measured in white and monochromatic light employing continuous band and line interference filters. The systematic error does not exceed 1&#x00B7;5 % of the values measured. The only aspect that distinguishes the miniphotometer from larger instruments is the limitation of spot size. A comprehensive test programme including comparative sets of measurements on a Zeiss MPM spectral microphotometer has shown that the results obtained by both instruments coincide well.</p></abstract>
</article-meta>
</front>
</article>